Ensure the sealing surfaces are clean, dry, and free of grease.
Position the gasket so that it is centered on the flange (use the bolts as a guide).
Lubricate the fasteners well. Be sure to lubricate all load bearing surfaces on the bolts, nuts, and washers.
Assemble bolts, washers and nuts on the flange.
Finger-tighten the bolts, moving in a circular direction.
Utilize a calibrated torque device to torque each bolt in a star pattern sequence. Apply the torque in three passes:
Apply the torque at 100% of Target Torque in a circular pass. Then wait 4 hours.
Complete the installation by performing circular passes until all bolts have acheived the target torque.
Residents of some states have the right to opt-out of the “sharing” or “selling” of their personal information. Gore does not "sell" the personal information of website users. Gore may "share" the personal information of website users, as standard advertising practice meant to offer you a more personalized service.
If you want to opt-out from Gore “sharing” your personal information, click on Opt-Out of Sharing to turn off the targeting cookies that we share with our advertising partners in order to provide you with personalized information. Disabling sharing will stop the use of cookies to targeted advertising but you may still see generic Gore ads.