GORE® TIGRIS® Vascular Stent Gains FDA Approval for Treatment of Peripheral Artery Disease
FLAGSTAFF, Ariz. (August 2, 2016) – W. L. Gore & Associates, Inc. (Gore) today announced the U.S. Food and Drug Administration (FDA) approval of the GORE® TIGRIS® Vascular Stent, a dual-component stent with a unique fluoropolymer / nitinol design. The GORE TIGRIS device, which gained CE Mark approval in 2011, is a third generation, self-expanding stent. The device was designed explicitly to improve anatomical conformability with the natural movement of the knee when treating Peripheral Artery Disease (PAD).
The newly-approved GORE TIGRIS Vascular Stent uses a dual component structure, made from a single-wire nitinol stent with flexible and biocompatible fluoropolymer interconnections. The stent has been designed to weather biomechanical forces (extension, compression, flexion and torsion) without fractures, even in the most complex anatomies, namely in the superficial femoral artery (SFA) and proximal popliteal artery (PPA). In the U.S. clinical study that supported FDA approval of the GORE TIGRIS Vascular Stent, the TIGRIS stent was found to have zero fractures, while the control arm devices experienced a 27 percent fracture rate.
“The TIGRIS Vascular Stent has an innovative design that is very different from any of the other nitinol stents that we currently use. The extreme flexibility of this stent makes it well suited for the superficial femoral artery and proximal popliteal artery, and the delivery system is highly accurate. The precision offered by this flexible, dual component device allows for easy insertion and predictable clinical outcomes, even in challenging anatomy,” said John R. Laird, MD, an interventional cardiologist in Davis, Calif.
The new device builds on the company’s long history and experience with stenting, which spans more than two decades. The GORE TIGRIS Vascular Stent also features Gore's CBAS Heparin Surface, the proven, lasting heparin bonding technology designed to resist thrombus formation, a problem common in both bare metal and drug-eluting stents. End-point covalent bonding keeps heparin anchored to the stent surface, while the bioactive site remains free to interact with the blood to help prevent clotting.
“At Gore, we pride ourselves in continuous evaluation of how our technologies can benefit patients. To design an uncovered stent that navigates and conforms to the complex anatomy of the artery, we leveraged our long history with endovascular devices to develop the GORE TIGRIS Vascular Stent. The addition of this device to our peripheral interventional portfolio enables physicians to treat more diverse cases with Gore’s best in class products,” said Ray Swinney, Business Unit Leader for the Gore Peripheral Interventional Business Unit.
The evolution of peripheral stenting over the past decade has allowed for broader adoption of endovascular therapy for treating PAD. When physicians began placing stents in the SFA they were limited by first generation stent designs that had longitudinal metal connections which led to arterial stiffening, high fracture rates and poorer clinical outcomes. Improvements in second generation devices introduced helical interconnections to improve flexibility; however, their success in high flexion vessels, like the distal SFA and PPA, was still limited.* The introduction of third generation stents, including the GORE TIGRIS Vascular Stent, allow for better adherence in some of the more intricate vessels in the body.
PAD is prevalent in older populations, a rapidly growing demographic in developed countries. In the U.S. alone, approximately 8 to 12 million people suffer from some form of PAD. The disease can manifest in mild symptoms such as chronic leg pain, and more serious complications include poor wound healing, increased risk of stroke, and amputation. Endovascular treatment, via angioplasty and stenting of a blocked artery, is designed to treat PAD without the complications that can accompany open surgery.
For more information on the GORE TIGRIS and the endovascular treatment of PAD, please visit www.goremedical.com/tigrisna
*Thaveau F, Méteyer V, LeJay A, Chakfé N. Latest generation of conforming dual component stent. In: Greenhalgh RM, ed. Charing Cross 2016-Vascular & Endovascular Challenges Update. 2016 ed. Fulham, London, United Kingdom: BIBA Publishing; 2016:423-428.
About W. L. Gore & Associates, Inc.
At Gore, we have provided creative therapeutic solutions to complex medical problems for 40 years. During that time, 40 million innovative Gore Medical Devices have been implanted, saving and improving the quality of lives worldwide. Our extensive family of products includes vascular grafts, endovascular and interventional devices, surgical meshes for hernia and soft tissue reconstruction, staple line reinforcement materials, and sutures for use in vascular, cardiac, and general surgery. We are one of a select few companies to appear on all of the U.S. “100 Best Companies to Work For” lists since the rankings debuted in 1984.
Products listed may not be available in all markets. GORE® and TIGRIS® are trademarks of W. L. Gore & Associates. ©2016 W. L. Gore & Associates, Inc.
CBAS is a trademark of Carmeda AB, a wholly owned subsidiary of W. L. Gore & Associates, Inc. AV0531-EN1 JULY 2016
Media Contact
Chempetitive Group for W. L. Gore & Associates
Andrea Vuturo
+1 312 997 2436
Contact by email